EMG 2 Micro Grid - Isolated parallel operation

EMG 2 Micro Grid - Isolated parallel operation

Training contents

  • Control of multiple generators in a stand-alone network
  • Control of multiple generators in parallel generation mode
  • Coordination of energy needs and generating capacity in stand-alone networks.
  • Use of modern information technology such as networked sensors/actuators, PLC control and the SCADA operating environment
  • Smart metering of a "slack bus" to make a sub-network autonomous.
  • Manual control
  • Voltage control
  • Frequency control
  • Torque control
  • Power factor (cos phi) control
  • Droop control
Supplementary Set comprising:
1
HMI (Human Machine Interface) for generators
HMI (Human Machine Interface) for generators CO3301-5L
1
Synchronization Unit
Synchronization Unit CO3212-6V
1
Power switch module
Power switch module CO3301-5P
1
Three-phase synchronous machine with smooth core rotor, 1 kW
Three-phase synchronous machine with smooth core rotor, 1 kW SE2682-5Q
Additionally required, dynamic servo machine test stand:
1
Servo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E)
Servo machine test stand for 1kW machines incl. software ActiveServo (D,GB,F,E) CO3636-6Y
1
Rubber coupling sleeve for 1kW machines
Rubber coupling sleeve for 1kW machines SE2662-6A
1
Coupling guard with LED lighting for 1kW machines
Coupling guard with LED lighting for 1kW machines SE2662-7D
Power supply:
1
Exciter voltage controller with de-excitation
Exciter voltage controller with de-excitation CO3301-5G
1
Motor protection switch, 3 pole, 1.8-2.5A
Motor protection switch, 3 pole, 1.8-2.5A CO3212-1P
1
Multiple socket outlet, 6 fold, with illuminated switch
Multiple socket outlet, 6 fold, with illuminated switch ST8010-4J
Accessories:
30
Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II SO5126-3R
5
Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II
Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V
5
Safety connecting plug 4mm with tap (2x), gr/ye, 1000V/32A CAT II
Safety connecting plug 4mm with tap (2x), gr/ye, 1000V/32A CAT II SO5126-3W
1
Set of safety measurement cables, 4mm, 31 pcs
Set of safety measurement cables, 4mm, 31 pcs SO5148-1L
1
Set of safety measurement cables, 4mm, 10m, 5 pcs, incl. fastening
Set of safety measurement cables, 4mm, 10m, 5 pcs, incl. fastening SO5148-1Z
1
Mobile aluminum experiment stand, 3 levels, power strip with 6 sockets,(1250 x 1970 x 700 mm)
Mobile aluminum experiment stand, 3 levels, power strip with 6 sockets,(1250 x 1970 x 700 mm) ST7200-4C
1
Protected power distribution for working stations
Protected power distribution for working stations ST8008-8N
Additionally recommended:
1
Display for Power Generation equipment
Display for Power Generation equipment ST8000-4J
1
Monitor holder for flat screen monitor of weight up to 15kg/33lbs
Monitor holder for flat screen monitor of weight up to 15kg/33lbs ST8010-4T
1
Keyboard adapter for flat screen monitor holders
Keyboard adapter for flat screen monitor holders ST8010-4G
1
Protection cover for three-level experiment trolleys
Protection cover for three-level experiment trolleys ST8010-9Y