EWI 1/2 Assembly exercises in building installation technology

EWI 1/2 Assembly exercises in building installation technology

The following exercises are performed in this course:

  • Wire stripping exercises

  • Wire and eyelet bending as well as wiring exercises

  • Techniques for surface and concealed installation of cables and conduits

  • Functions and usage of automatic circuit-breakers

  • Disconnection (conduit installation)

  • Disconnection with a control lamp and socket

  • Multiple switch, two-way and intermediate switch circuits with a socket

  • Extension of a double switch circuit with a socket into a double switch economy circuit

  • Current-surge circuit with a socket

  • Staircase timer circuit with a timing relay

  • Testing and commissioning of the circuits in accordance with installation and circuit diagrams

  • Configuration of circuits in conduits or cable installations for fluorescent lamp circuits

  • On/off circuit with a fluorescent lamp and socket

  • Dual (lead-lag) circuit with a fluorescent lamp and socket

  • Tandem circuit with a fluorescent lamp and socket

 
Equipment set comprising the following:
1
Set of installation materials, EWI 1
Set of installation materials, EWI 1 SE2670-1A
1
Set of installation materials, EWI 2
Set of installation materials, EWI 2 SE2670-1C
1
Set of fixing materials, cables
Set of fixing materials, cables SE2670-1G
1
Set of fastening materials
Set of fastening materials SE2670-1J
1
Set of wiring materials, EWI 1-2
Set of wiring materials, EWI 1-2 SE2670-1M
Media:
1
Manual EWI 1/2 Assembly practice on wiring inst. and fluor.light. circuits (GB)
Manual EWI 1/2 Assembly practice on wiring inst. and fluor.light. circuits (GB) SH5001-3A
Power supply:
1
Adapter box, three-phase / 4mm
Adapter box, three-phase / 4mm SE2661-9R
Measuring instruments:
1
Voltage, phase + continuity tester with field direction indicator, max. 400V
Voltage, phase + continuity tester with field direction indicator, max. 400V LM8554
1
Multi13S digital multimeter
Multi13S digital multimeter LM2330
Accessories:
1
Storage tray for SE boxes, reinforced, for 10 boxes
Storage tray for SE boxes, reinforced, for 10 boxes ST7004-2B
2
Storage tray for installation materials I, reinforced base
Storage tray for installation materials I, reinforced base ST7004-2J
1
Set of fixing materials, punched hole frame
Set of fixing materials, punched hole frame SE2669-3A
1
Set of fixing materials, punched hole frame (100pcs)
Set of fixing materials, punched hole frame (100pcs) SE2669-3C
1
Set of tools ''Electric ''
Set of tools ''Electric '' SE2670-4B
5
Safety measurement cable (4mm), 100cm, black
Safety measurement cable (4mm), 100cm, black SO5126-8V
1
Safety measurement cable (4mm), 100cm/40", blue
Safety measurement cable (4mm), 100cm/40", blue SO5126-9A
1
Safety measurement cable (4mm), 100cm, green/yellow
Safety measurement cable (4mm), 100cm, green/yellow SO5126-9C
1
Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm
Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A
1
Punched hole panel, interchangeable, for 1200mm panel mounting frames
Punched hole panel, interchangeable, for 1200mm panel mounting frames ST8003-5Q

Alternative Montagemöglichkeit: 

1
Punched hole wiring installation cabin kit, 3 sides + roof, inside 1.2 x 1.2 x 2.0
Punched hole wiring installation cabin kit, 3 sides + roof, inside 1.2 x 1.2 x 2.0 ST8003-6C
1
Ergo45° 3 HU power duct, 580 mm, for twin wiring installation cabin, horizontal 114 PU
Ergo45° 3 HU power duct, 580 mm, for twin wiring installation cabin, horizontal 114 PU ST8033-3U
1
Full-width front plate (type 1) for six-sided power supply duct 114PU
Full-width front plate (type 1) for six-sided power supply duct 114PU ST8070-4C