EUG 3/4 Pumped storage power plant/Power plants

EUG 3/4 Pumped storage power plant/Power plants

In the power plants course, the way the following types of power plant operate is covered:

  • Lignite power plants
  • Coal-fired power plants
  • Gas turbine power plants
  • Gas and steam power plants
  • Biogas combined heat and power (cogeneration) plants
  • Nuclear power plants
  • Hydroelectric power plants

The pumped storage power plant course analyses how electrical energy can be stored by transforming it into potential energy of water and then transforming it back into electrical energy again for feeding to the grid. Pumped storage plants are becoming increasingly necessary due to the increase in renewable energy generation and also provide indispensable energy storage capacity in a high-quality smart grid.

Training contents:

  • Setting up synchronisation
    • Putting a multi-function relay into operation
  • Generator operation
  • Grid synchronisation
    • Setting parameters for a multi-function relay
    • Automatic synchronisation
  • Manual power regulation for generators and motors
  • Generator control using SCADA
  • Power plants
    • Types of power plant
    • Typical characteristic curves and parameters
    • Commissioning and operation of various types of power station
    • Finding out how power plants work
    • Automatic load following with externally measured active and reactive power
  • Pumped storage power plants in a smart grid
Basic equipment set, consisting of: 
1
HMI (Human Machine Interface) for generators
HMI (Human Machine Interface) for generators CO3301-5L
1
Synchronization Unit
Synchronization Unit CO3212-6V
1
Multi-function relay, power controller, cos-phi controller, synchronizing unit
Multi-function relay, power controller, cos-phi controller, synchronizing unit CO3301-5W
1
Power switch module
Power switch module CO3301-5P
1
Variable Ohmic load, three-phase, 1kW
Variable Ohmic load, three-phase, 1kW CO3301-3F
1
Inductive load, three-phase, 1kW
Inductive load, three-phase, 1kW CO3301-3D
1
Three-phase synchronous machine with smooth core rotor, 1kW
Three-phase synchronous machine with smooth core rotor, 1kW SE2662-5Q
Additionally required, dynamic servo machine test stand:
1
Servo machine test bench for 1kW machines incl. ActiveServo software(D,GB,F,E)
Servo machine test bench for 1kW machines incl. ActiveServo software(D,GB,F,E) CO3636-6W
1
Rubber coupling sleeve, 1kW
Rubber coupling sleeve, 1kW SE2662-6A
1
Coupling guard, 1kW
Coupling guard, 1kW SE2662-6B
1
Shaft end guard, 1kW
Shaft end guard, 1kW SE2662-6C
1
QuickChart, Servo-machine test stand safety and operating instructions (GB)
QuickChart, Servo-machine test stand safety and operating instructions (GB) SO6200-7D
Power supply:
1
Universal power supply for electrical machines
Universal power supply for electrical machines CO3212-5U
1
Exciter voltage controller with de-excitation
Exciter voltage controller with de-excitation CO3301-5G
1
Motor protection switch, 3 pole, 1.8-2.5A
Motor protection switch, 3 pole, 1.8-2.5A CO3212-1P
1
Multiple socket outlet, 6 fold, with illuminated switch
Multiple socket outlet, 6 fold, with illuminated switch ST8010-4J
Measuring instruments:
1
Three-phase power quality meter, display and long-term memory
Three-phase power quality meter, display and long-term memory CO5127-1S
Media:
1
Interactive Lab Assistant: Pumped-Storage power station
Interactive Lab Assistant: Pumped-Storage power station SO2800-9T
1
Interactive Lab: Power Plants
Interactive Lab: Power Plants SO2800-9U
Additionally recommended
1
Interactive Lab Assistant: AC Synchronisation and Automatic Generator Control
Interactive Lab Assistant: AC Synchronisation and Automatic Generator Control SO2800-9E
1
Interactive Lab Assistant: Generator protection
Interactive Lab Assistant: Generator protection SO2800-9G
Software:
1
Patch cable Cat5E 1x 1m yellow, 2x 2m yellow
Patch cable Cat5E 1x 1m yellow, 2x 2m yellow LM9057
1
USB Network Adapter 10/100 BaseTX RJ45
USB Network Adapter 10/100 BaseTX RJ45 LM9056
1
5-Port Ethernet Switch
5-Port Ethernet Switch LM9988
Accessories:
1
Double busbar unit, three-phase, incoming / outgoing feeder
Double busbar unit, three-phase, incoming / outgoing feeder CO3301-5R
40
Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II
Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II SO5126-3R
2
Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II
Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V
2
Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II
Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II SO5126-3W
1
Set of safety measurement cables, 4mm (31 leads)
Set of safety measurement cables, 4mm (31 leads) SO5148-1L
2
Safety measurement cable (4mm), 150cm, brown
Safety measurement cable (4mm), 150cm, brown SO5126-9J
2
Safety measurement cable (4mm), 150cm, black
Safety measurement cable (4mm), 150cm, black SO5126-9G
2
Safety measurement cable (4mm), 150cm, grey
Safety measurement cable (4mm), 150cm, grey SO5126-9N
2
Safety measurement cable (4mm), 150cm, blue
Safety measurement cable (4mm), 150cm, blue SO5126-9K
1
Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm
Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A
1
Protected power distribution for working stations
Protected power distribution for working stations ST8008-8N
1
Wall or aluminium-profile mounting cable storage for 48 cables
Wall or aluminium-profile mounting cable storage for 48 cables ST8003-8E
1
PC holder for SybaPro experiment trolleys, height/width adjustable
PC holder for SybaPro experiment trolleys, height/width adjustable ST7200-5F
1
Monitor holder for flat screen monitor of weight up to 15kg / 33lbs
Monitor holder for flat screen monitor of weight up to 15kg / 33lbs ST8010-4T
1
Keyboard adapter for flat screen monitor holders
Keyboard adapter for flat screen monitor holders ST8010-4G
1
Protection cover for three-level experiment trolleys
Protection cover for three-level experiment trolleys ST8010-9Y